Issue

Tableau Server 2018.2 upgrade fails under initialization step 14 - Migrations.

Environment

  • Tableau Server 2018.2.1

Resolution

Upgrade to Tableau Server 2018.2.2.

Cause

TSM fails to initialize at step 13 if the time zone on the Tableau Server machine is set to UTC-11 or UTC-12.
This issue is related to known issue 769924 which has been fixed in Tableau Server version 2018.2.2.