Issue

Extract refreshes scheduled in Tableau Bridge 2018.2 may fail with the following error:
status code=3001. Failed to refresh data source: <data source name> due to the followin gerror:
IPC_NamedPipe::Select(WaitForMultipleObjects): Timeout. Tabprotosrv cannot start or shut down unexpectedly.
Unable to connect to the server "<server name>".
Check that the server is running and that you have access privileges to the requested database.

Refreshes in Tableau Bridge 2018.1 and Tableau Desktop 2018.2 succeed.

Environment

  • Tableau Bridge 2018.2

Cause

Known Issue 808869 in Tableau Bridge 2018.2 caused extract refreshes to fail in certain environments.  This issue was resolved in Tableau Bridge 2018.3.0.18.1016.2147.