KNOWLEDGE BASE

Interactive Microservice Container Process Moved to Error State Frequently


Published: 27 Jul 2022
Last Modified Date: 27 Jul 2022

Issue

The Interactive Microservice Container process is in a stopped state frequently.  The process continues to error out even when brought up manually.

Environment

  • Tableau Server 
  • Windows Server 

Resolution

   Create a backup of Tableau Server, obliterate the current installation and change the hostname to have no trailing dash ("-") or hyphen ("_")  character.   Re-install the same version of Tableau Server and restore with the backup. 

Cause

The hostname has a trailing hyphen character "-" such as, "tableau-server-".   