KNOWLEDGE BASE

Extract Refresh Via Tableau Bridge Fails With "VConDownstreamExtractsWithWarnings" Message using Extract from Desktop 2023.1


Published: 27 Apr 2023
Last Modified Date: 03 May 2023

Issue

After creating an extract using Tableau Desktop 2023.1 or newer, and using a Tableau Bridge version released prior to 2023.1 to refresh the extract, the refresh fails with the following error:

VConDownstreamExtractsWithWarnings

Environment

  • Tableau Desktop 2023.1
  • Tableau Bridge release prior to 2023.1
  • Tableau Cloud

Resolution

Option 1:

Use Tableau Desktop 2022.4 or an older version to create the extract of the data source.


Option 2:

Upgrade Tableau Bridge to 2023.1 or newer version. For more details, see Upgrade Bridge.  Tableau Bridge downloads are available from the Tableau release website.

Cause

There is a compatibility issue between Tableau Desktop 2023.1 and the old version of Tableau Bridge.
Did this article resolve the issue?